Made in USA P010535 Rev. E 09/11 PUREGAS LLC 226A Commerce Street Broomfield, CO 80020 Tel: 800-521-5351 Fax: 303-657-2205 [email protected] w
Page 7 of 24 Note: All dimensions are in inches FIGURE 6: DIMENSIONS OF PMD AND TOC MODELS MODEL PMD
Page 8 of 24 Recommended Installation Diagram A diagram of the recommended installation is below. It depicts all of the essential elements of a pro
Page 9 of 24 outlet can be changed if necessary. This is accomplished by detaching the shuttle valve from the tower and reassembling it with the des
Page 10 of 24 or flow variation, PUREGAS manufactures various tanks, which will completely eliminate downstream pressure surges. IMPORTANT! For opt
Page 11 of 24 minimize the outlet pressure and flow variation, as well as desiccant shock as the flow switches from one chamber to the other. The PC
Page 12 of 24 The sizing of the purge orifice is also important to the performance of a PSA system. The orifice must be large enough to admit suffi
Page 13 of 24 SECTION 4 - MAINTENANCE General Information When properly installed and operated, PUREGAS compressed air dryers and adsorbers are desi
Page 14 of 24 Purge Mufflers: Remove the mufflers from the solenoid valves and check for excessive pressure drop by blowing through the muffler. T
Page 15 of 24 SECTION 5 – REPLACEMENT PARTS General Information The following exploded view drawings and tables show the available replacement parts
Page 16 of 24 FIGURE 10: REPLACEMENT PARTS FOR PHF, PCDA, PHCA AND PCME MODELS REPLACEMENT PARTS MODEL SIZE PART NUMBERDesiccant TowerPHF 6", B
Instruction Manual for PUREGAS Compressed Air Dryers and Adsorbers IMPORTANT NOTE! LIMITED WARRANTY AGREEMENT CAUTION! This instruction manual
Page 17 of 24 FIGURE 11: EXPLODED VIEW OF PCR MODEL
Page 18 of 24 FIGURE 12: REPLACEMENT PARTS FOR PCR MODEL REPLACEMENT PARTS MODEL SIZE PART NUMBERDesiccant TowerPCR-15B 15", Black P010764-F
Page 19 of 24 FIGURE 13: EXPLODED VIEW OF PMD AND TOC MODELS
Page 20 of 24 FIGURE 14: REPLACEMENT PARTS FOR PMD AND TOC MODELS REPLACEMENT PARTS MODEL SIZE PART NUMBERDryer Maintenance Kit**PMD-Sn/a P01
Page 21 of 24 SECTION 6 – TROUBLESHOOTING INFORMATION General Information The following troubleshooting guide is intended to assist in the analys
Page 22 of 24 Problem A: Expected outlet dewpoint or purity is not met. Model Potential Cause Verification Corrective Action A1 All Cu
Page 23 of 24 Problem B: Excessive purge flow or blowdown. Model Potential Cause Verification Corrective Action B1 All The purge orifi
Page 24 of 24 Problem C: Excessive pressure drop across unit. Model Potential Cause Verification Corrective Action C1 All Current operat
Instruction Manual for PUREGAS Compressed Air Dryers and Adsorbers Table of Contents SECTION 1 – GENERAL...
Page 1 of 24 SECTION 1 – GENERAL Scope of Manual This instruction manual is intended to assist our customers with the installation, operation, and
Page 2 of 24 Please consult the factory PRIOR to installing a unit for any application other than air or inert gases. Use with certain liquids or ga
Page 3 of 24 Operation of PCR Model As previously described, the PCR model employs PSA technology to effectively remove moisture (or other unwanted
Page 4 of 24 Operation of PMD and TOC Models The PMD and TOC models also employ Pressure Swing Adsorption (PSA) technology to remove water vapor an
Page 5 of 24 SECTION 3 – INSTALLATION AND OPERATION Inspection Remove the compressed air dryer or adsorber from the shipping carton. Inspect the u
Page 6 of 24 MODEL A B C D E F PCR 15 18.625 6 25.5 3.25 5.5 8.25 PCR 25 22.935 6 30 4.25 6.4 9.25 PCR 50 28.125 6 35.