Puregas TOC Manuel d'instructions

Naviguer en ligne ou télécharger Manuel d'instructions pour Sèche-linge électrique Puregas TOC. Puregas TOC Instruction manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 27
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
Made in USA P010535 Rev. E 09/11
PUREGAS
LLC
226A Commerce Street
Broomfield, CO 80020
Tel: 800-521-5351
Fax: 303-657-2205
www.puregas.com
Instruction Manual
for PUREGAS
Compressed Air Dryers
and Adsorbers
Models: PHF
PCR
PCDA
PHCA
PCME
PMD
TOC
Vue de la page 0
1 2 3 4 5 6 ... 26 27

Résumé du contenu

Page 1

Made in USA P010535 Rev. E 09/11 PUREGAS LLC 226A Commerce Street Broomfield, CO 80020 Tel: 800-521-5351 Fax: 303-657-2205 [email protected] w

Page 2

Page 7 of 24 Note: All dimensions are in inches FIGURE 6: DIMENSIONS OF PMD AND TOC MODELS MODEL PMD

Page 3 - Figures

Page 8 of 24 Recommended Installation Diagram A diagram of the recommended installation is below. It depicts all of the essential elements of a pro

Page 4 - Page 1 of 24

Page 9 of 24 outlet can be changed if necessary. This is accomplished by detaching the shuttle valve from the tower and reassembling it with the des

Page 5 - Page 2 of 24

Page 10 of 24 or flow variation, PUREGAS manufactures various tanks, which will completely eliminate downstream pressure surges. IMPORTANT! For opt

Page 6 - Page 3 of 24

Page 11 of 24 minimize the outlet pressure and flow variation, as well as desiccant shock as the flow switches from one chamber to the other. The PC

Page 7 - Page 4 of 24

Page 12 of 24 The sizing of the purge orifice is also important to the performance of a PSA system. The orifice must be large enough to admit suffi

Page 8 - Page 5 of 24

Page 13 of 24 SECTION 4 - MAINTENANCE General Information When properly installed and operated, PUREGAS compressed air dryers and adsorbers are desi

Page 9

Page 14 of 24  Purge Mufflers: Remove the mufflers from the solenoid valves and check for excessive pressure drop by blowing through the muffler. T

Page 10

Page 15 of 24 SECTION 5 – REPLACEMENT PARTS General Information The following exploded view drawings and tables show the available replacement parts

Page 11

Page 16 of 24 FIGURE 10: REPLACEMENT PARTS FOR PHF, PCDA, PHCA AND PCME MODELS REPLACEMENT PARTS MODEL SIZE PART NUMBERDesiccant TowerPHF 6", B

Page 12 - Page 9 of 24

Instruction Manual for PUREGAS Compressed Air Dryers and Adsorbers IMPORTANT NOTE! LIMITED WARRANTY AGREEMENT CAUTION! This instruction manual

Page 13 - Page 10 of 24

Page 17 of 24 FIGURE 11: EXPLODED VIEW OF PCR MODEL

Page 14

Page 18 of 24 FIGURE 12: REPLACEMENT PARTS FOR PCR MODEL REPLACEMENT PARTS MODEL SIZE PART NUMBERDesiccant TowerPCR-15B 15", Black P010764-F

Page 15

Page 19 of 24 FIGURE 13: EXPLODED VIEW OF PMD AND TOC MODELS

Page 16

Page 20 of 24 FIGURE 14: REPLACEMENT PARTS FOR PMD AND TOC MODELS REPLACEMENT PARTS MODEL SIZE PART NUMBERDryer Maintenance Kit**PMD-Sn/a P01

Page 17 - Page 14 of 24

Page 21 of 24 SECTION 6 – TROUBLESHOOTING INFORMATION General Information The following troubleshooting guide is intended to assist in the analys

Page 18 - Page 15 of 24

Page 22 of 24 Problem A: Expected outlet dewpoint or purity is not met. Model Potential Cause Verification Corrective Action A1 All Cu

Page 19 - Page 16 of 24

Page 23 of 24 Problem B: Excessive purge flow or blowdown. Model Potential Cause Verification Corrective Action B1 All The purge orifi

Page 20

Page 24 of 24 Problem C: Excessive pressure drop across unit. Model Potential Cause Verification Corrective Action C1 All Current operat

Page 21

Instruction Manual for PUREGAS Compressed Air Dryers and Adsorbers Table of Contents SECTION 1 – GENERAL...

Page 22 - Page 19 of 24

Page 1 of 24 SECTION 1 – GENERAL Scope of Manual This instruction manual is intended to assist our customers with the installation, operation, and

Page 23

Page 2 of 24 Please consult the factory PRIOR to installing a unit for any application other than air or inert gases. Use with certain liquids or ga

Page 24

Page 3 of 24 Operation of PCR Model As previously described, the PCR model employs PSA technology to effectively remove moisture (or other unwanted

Page 25

Page 4 of 24 Operation of PMD and TOC Models The PMD and TOC models also employ Pressure Swing Adsorption (PSA) technology to remove water vapor an

Page 26

Page 5 of 24 SECTION 3 – INSTALLATION AND OPERATION Inspection Remove the compressed air dryer or adsorber from the shipping carton. Inspect the u

Page 27

Page 6 of 24 MODEL A B C D E F PCR 15 18.625 6 25.5 3.25 5.5 8.25 PCR 25 22.935 6 30 4.25 6.4 9.25 PCR 50 28.125 6 35.

Commentaires sur ces manuels

Pas de commentaire